A46
Alarm code A46 means .
Cause analysis: Multi-turn information overflow.
Remedy:
-
For prolonged operation in one direction, try setting PN007.1=1 to disable it;
-
Clear it by performing FN010 and FN011. If the robot has lost its zero point, perform robot homing;
-
Ensure that the battery voltage in the battery box is 3.6v;