Category: Alarm
Cause
Condition: The servo drive estimates inertia abnormally during automatic tuning. Causes:
- Acceleration/deceleration time is too long.
- Rotation speed is too low.
- Mechanical load inertia is too large.
- Mechanical inertia changes too abruptly.
Corrective action
- Acceleration/deceleration time between 0 rpm and 3,000 rpm must be no more than 1.5 seconds.
- Minimum speed must be at least 200 rpm; at least 500 rpm is recommended.
- Load inertia must be no more than 50 times motor inertia.
- Not suitable for applications with excessively abrupt inertia ratio changes. Reset the alarm.