8544
Category: Alarm
Cause
- Incorrect cable wiring or poor contact between the serial conversion unit and servo unit
- The specified cable is not used between the serial conversion unit and servo unit
- Excessive cable length between the serial conversion unit and servo unit
- Damaged cable jacket between the serial conversion unit and servo unit
Corrective action
- Check external encoder wiring; correctly wire the cable between the serial conversion unit and servo unit.
- Check external encoder cable specifications; use the correct specified cable.
- Change the serial conversion unit connection cable length; keep the cable between the serial conversion unit and servo unit within 20m.
- Check the serial conversion unit connection cable; replace the cable between the serial conversion unit and servo unit.