Error handling: Motor power OFF.
Error reset: Possible.
Description: A sharp rise in PN voltage is detected when the motor power is turned ON.
Main causes:
-
The PN capacitor is not connected.
-
A problem with the PN capacitor.
-
The power supply unit is faulty.
Countermeasures:
-
Check whether the PN capacitor in the power supply unit is connected.
-
Replace the PN capacitor.
-
Replace the power supply unit.