8135
Category: Alarm
Cause
Condition: Too many motor control functions are enabled in the drive. Cause: Drive function utilization alarm.
Corrective action
- Check the currently enabled filters and determine whether they are necessary.
- Set P2.066 [Bit 4] to 1 to suppress display of this alarm.
- Disable unnecessary filters, such as low-pass smoothing filters (P1.006 ~ P1.008), Moving filter (P1.068), low-frequency vibration suppression (P1.025 ~ P1.028), flexibility compensation (P1.089 ~ P1.094), Notch filter (first through fifth groups), friction compensation percentage (P1.062), and motor collision protection - torque percentage (P1.057).
- Set P2.066 [Bit 4] to 1, then supply power again.