1333
Category: Alarm
Cause
The actual position or target position exceeds the maximum permitted range
Corrective action
- Execute the Encoder Multi-turn Clear command and ensure that the motor operating range does not exceed the maximum permitted range
- If the motor must operate over a large range, enable unlimited position control using servo parameter 0x2000