Error handling: Motor power OFF.
Error reset: Possible.
Description: A mismatch between the output current state and current feedback was detected at the motor ON output section on the power supply unit control board (1VH).
Main causes:
-
The power supply unit control board is faulty.
-
The wiring between the X320 connectors (24V brake power supply system) on the power supply unit control board has a poor connector connection, open circuit, or similar fault.
-
A problem with the power supply unit power board.
-
A problem with the Motor ON output system (X313 connector section) from the power supply unit. (Note: A jumper is connected between A1-B1 by default.)
Countermeasures:
-
Replace the power supply unit.
-
Check the wiring connected to X320.
-
Replace the motherboard.
-
Check the motor ON output system (X313 connector section) from the power supply unit for short circuits, open circuits, etc.