Error handling: Motor power OFF.
Error reset: Not possible.
Description: The I/O board failed to start when the controller power was turned ON. The causes do not include the following errors:
E1009: I/O board XX is not installed. D2056 [I/O board (NoXX)]: The same address ID is set on several boards.
Main causes:
-
The AS software package is installed incorrectly.
-
The CF card of the main CPU board is faulty.
-
The main CPU board is faulty.
Countermeasures:
-
Turn the controller power OFF and then ON again. If an initialization message appears, select .
-
If the fault always occurs at a particular program step or during a particular operation, report all details to Kawasaki service, including the full message, robot model, controller model, machine number, AS/servo software versions, operation when the error occurred, program listing, optional functions, etc.
-
If the phenomenon cannot be reproduced or the program cannot be restored to normal, replace the CF card or main CPU board.
-
Reinstall the AS software package.