Description
The ASF01 board is configured by duplicated systems to check operations each other. Either of the duplicated systems has detected abnormal voltage of the other system
Subcode description
Over voltage error detected in
the 24.0V supply line.
Causes and remedies
| Cause | Remedy |
|---|---|
| ASF01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ASF01 board. Save CMOS.BIN before replacing the board. |