Description
The position exceeds the allowable range of External Motion Interface correction arg, mechanical unit arg joint arg.
Consequences
Program execution will stop and the system will enter the "motor off" state.
Possible causes
The value of the position offset path or last fine point exceeds the maximum allowed value.
Recommended actions
Check the application that is using the External Motion Interface function, increase the maximum allowed position value, or modify the program setting position to be closer to the target position.