Description
An internal control error occurred at offline position data conversion.
Subcode description
The inverse shift data for
welding path shift function could
not correctly be calculated.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (malfunction) | 1. Reset the alarm, select the utility to cancel seam coordinates, abort seam shifting, and execute the job again. 2. If the alarm recurs after taking the corrective actions, save CMOS.BIN and report the circumstances (operating procedure, etc.) to our service department. |