Description
An error occurred in calibration teaching between manipulators.
Subcode description
The 2nd-axis positions of C3,
C4, and C5 of station axes are
not the same.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Change the teaching so that station axis No. 2 of C3, C4, and C5 is at the same position. |