Description
The parameter setting do not match to system configuration setting.
Subcode description
The parameter setting is
incorrect.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Start maintenance mode, display the control group setting screen, and check that the following items match the system configuration. 1. When the system uses a STO connection • Servo board connected to the control group • Number of axes connected to the servo board connectors • Contactor unit connected to the brake • Converter connected to the axis • ON_ENABLE signal connected to the control group • Overrun signal settings 2. When the system uses a contactor connection • Servo board connected to the control group • Number of axes connected to the servo board connectors • Axis numbers connected to the servo board connectors • Converter connected to the axis • Contactor unit connected to the brake • Overrun signal settings |
| ASF01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ASF01 board. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |