[Cause]
A cylinder could not be detected in the acquired 3-dimensional map. Possible causes include:
1. Insufficient 3-dimensional map data.
2. There are no cylinders suitable for measuring the 3-dimensional point cluster in the area.
[Countermeasure]
For their respective reasons, the response is as follows:
1. Reset 3-D map data acquisition conditions.
2. Adjust Minimum Valid Score and Cylinder Error Tolerance for 3-dimensional wide-area sensor cylinder detection.
PAUSE.G No cylinder found (This alarm is displayed on R-30iB Plus, R-30iB Mate Plus controllers.)
[Cause]
A cylinder could not be detected in the acquired 3-dimensional map. Possible causes include:
1. Insufficient 3-dimensional map data.
2. There are no cylinders suitable for measuring the 3-dimensional point cluster in the area.
[Countermeasure]
For their respective reasons, the response is as follows:
1. Reset 3-D map data acquisition conditions.
2. Adjust Minimum Valid Score and Cylinder Error Tolerance for 3D cylinder detection.