[Cause]
An attempt was made to set a process number that already has a sub-process for inserting in the advanced data "custom parent number" of the process set in insert.
[Countermeasure]
For a parameter program table, only one matching sub-parameter program table can be specified. Make any of the following changes:
1 When you want to set the new process as an insert sub-process, set the "custom parent number" of the existing insert sub-process to 0, and then set it in the new process Reassign the "Custom Parent Number" in .
2. If the specified parent process number is incorrect, specify the correct parent process number. 3. If a retry (pull-out) subprocess was intended, the retry (pull-out) subprocess has the following characteristics: ① The user and tool coordinate systems are the same as those of the parent process; ② the insertion axis is the same but the sense is opposite (for example, if the parent's insertion direction is −Z, the retry (pull-out) subprocess insertion direction is +Z). After setting ① and ② correctly, set ‘Custom parent number’.