[Cause]
The elapsed time from reaching the SS taught point until the air signal turns on is too long. The elapsed time from reaching the SE taught point until the air signal turns off is too long. This alarm occurs when the settings cause the air signal to turn on or off 100ms or more after reaching the taught point of the dispensing instruction.
[Countermeasure]
Increase the "Mist Air ON/OFF Delay" and "Device Delay", or decrease the "Glue Gun ON/OFF Too Late".