Description
An error occurred during the SDCA01 board control check.
Subcode description
The setting value for touch
pressure is not appropriate.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | The contact pressure setting in the gun detailed settings file (ratio to the first pressure force) exceeds 100%. Set a value no greater than 100. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |