Description
Incorrect analog output port selection parameter The value of the parameter AxP010 indicating the leading number of analog output port used for arc welding or sealing application was incorrect.
Subcode description
Sub Code: Application number
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Check the following settings. • Set the following values in parameter AxP010: - Arc welding application: 1 - Arc welding + arc welding: 3 - Three arc-welding robots: 5 - Four arc-welding robots: 7 |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |