Description
A communication error occurred between machine safety and the ACP01 board.
Subcode description
The ACP01 board did not respond within the specified time.
Causes and remedies
| Cause | Remedy |
|---|---|
| Cable (abnormal) | Check the connection and insertion of the following boards. • ACP01 board • AIF01 board • ASF01 board |
| ASF01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ASF01 board. |
| ACP01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ACP01 board. After replacing the ACP01 board, remove the SD card from the original ACP01 board and insert it into the new ACP01 board. |
| AIF01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the AIF01 board. Save CMOS.BIN before replacing the board. After replacing the AIF01 board, load the saved CMOS.BIN file. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |