Description
A communication error occurred between the AIF01 board and the ASF01 board.
Subcode description
Data consistency error
Causes and remedies
| Cause | Remedy |
|---|---|
| Cable (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, check that the following cables and connectors are connected and fully inserted. • SDCA01 board-CN515 • AIF01 board-CN113 • CNBX connectors on the SDCA01 board and ASF01 board |
| ASF01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ASF01 board. Save CMOS.BIN before replacing the board. |
| AIF01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the AIF01 board. Save CMOS.BIN before replacing the board. Load CMOS.BIN after replacing the AIF01 board. |
| Software (malfunction) | 1. Turn the power off and back on. 2. If the alarm recurs, save CMOS.BIN and report the circumstances (operating procedure, etc.) to our service department. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |