Cause:
The parameters in the bending variable are set incorrectly, for example, speed and acceleration parameters in the bending variable are set to non-positive values.
Troubleshooting:
Check whether each parameter of the bending variable is correct on the bending configuration screen.
Solution:
Modify the parameters of the bending variable.
Case sharing:
For example, if the bending speed, acceleration, and jerk of bending variable benddata0 are all set to 0, running BendTrack(benddata0) reports error 385.