Description
Task: arg.
The calculated logical output value of the argument in the TriggSpeed instruction ScaleValue and the programming speed in the current instruction exceed the maximum physical output value of the analog signal used in the argument of the TriggSpeed instruction AOp.
Program reference arg.
Possible causes
The logic simulation output exceeds the force output value.
Logic output value = scale value * programmed TCP speed (units are mm/s). The physical output value of the analog signal = the corresponding definition of the actual analog output signal. Analog signals can only be set between arg and arg according to I/O system parameter configuration.
Recommended actions
Reduce the value used in ScaleValue, or reduce the currently specified programming speed. Another solution is to modify the configuration value of the analog output signal.
Recovery: arg.