Description
Setup process of MOTION section was not properly completed when the power turned ON.
Subcode description
The servo control section cannot
receive the position data of when
the power supply was turned
OFF
Causes and remedies
| Cause | Remedy |
|---|---|
| SDCA01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the SDCA01 board. As a precaution, save CMOS.BIN before replacing the board. |
| Software (malfunction) | 1. Turn the power off and back on. 2. If the alarm recurs, save CMOS.BIN and report the circumstances (operating procedure, etc.) to our service department. |