Description
This alarm occurs if abnormal internal data is detected during the access to position data.
Subcode description
The memory size of the position
data exceeded the maximum
memory size at the initialization
of the position data control
process.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (malfunction) | 1. Reset the alarm. 2. If this happens again, delete the job where the alarm occurred. 3. If the alarm recurs despite the above measures, initialize the job in maintenance mode and reload the saved job. |