Description
An error occurred when execution of auto PMT.
Subcode description
The memory area for job area is
insufficient.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (malfunction) | 1. Reset the alarm. 2. If this happens again, delete unused jobs. 3. If the alarm recurs despite the above measures, initialize the job in maintenance mode and reload the saved job. In this case, delete unused jobs. 4. If the alarm recurs despite the above measures, save CMOS.BIN and report the circumstances (operating procedure, etc.) to our service department. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |