[Cause]
Illegal encoder numbers are specified in the tracking parameter settings used in the program or in the tracking instructions.
[Countermeasure]
Check the value of system variable $LNSCH[n].$TRK_ENC_NUM (n is the tracking parameter setup table number, an item on the tracking program detail screen) and the parameter value of tracking instruction LINE[], and ensure that they are within the valid range.