1674
Category: Alarm
Cause
When not enabled:
- Drive model does not match
- Encoder wiring incorrect When enabled:
- Speed command exceeds the maximum speed setting;
- UVW phase sequence incorrect;
- Severe speed response overshoot;
- Drive fault
Corrective action
When not enabled:
- Contact the manufacturer
- Confirm correct encoder wiring When enabled:
- Reduce the speed command;
- Check whether the UVW phase sequence is correct;
- Adjust the speed loop gain to reduce overshoot;
- Replace the drive