Description
An error occurred during the SDCA01 board control check.
Subcode description
Direct-in number setting error
(NSRCH)
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | The NSRCH instruction simultaneously specifies 3 or more direct input numbers. Check the direct input number setting in the NSRCH instruction. |