Description
When automatic mode is requested, one or more NORMAL (normal) tasks are disabled and cannot be enabled.
Consequences
The system cannot enter automatic mode.
Possible causes
Unable to reset Task Selection Panel in sync block.
Recommended actions
- Switch back to manual mode.
- a ) Set PP as the main program. b ) or exit the sync block. c ) or when switching to automatic, if the system should be in debug mode, set "system parameter Controller"/"Auto Condition Reset"/"All Debug Settings"/"Reset" to "No".
- Switch back to automatic mode and confirm.