8547
Category: Alarm
Cause
Servo ON occurs while position deviation is at or above the Pn526 setting during servo ON
Corrective action
Check position deviation (Un008) at servo ON; configure clearing of position deviation at servo ON, or set the correct excessive position deviation alarm value at servo ON (Pn526).