Error handling: Motor power OFF.
Error reset: Possible.
Description: On the power supply unit control board (1VH), the independent power cutoff contact states connected to connector X301 do not match between safety circuits 1 and 2.
Main causes:
-
There is a problem with the wiring to connector X301 on the power supply unit control board (1VH) (such as only the first contact being connected), or there is a contact problem.
-
The power supply unit control board is faulty.
Countermeasures:
-
Check the wiring or connection of the X301 connector.
-
Replace the power supply unit control board.
Reference: Select <Display 1> → → <Safety Circuit Monitor 2> on the teach pendant screen to check the safety circuit status. For details of safety circuit input monitoring, refer to the Operation Manual.

[NOTE]
- This error does not occur if the safety circuit is configured as a single circuit.
- This error can be reset only when the single and double circuits are both open (OFF) at the same time. If either circuit is closed, the error cannot be reset.