8107
Category: Alarm
Cause
Condition: calibration value exceeds the permitted value during electrical calibration. Causes:
- Analog input contacts not correctly zeroed.
- Detection component damaged.
Corrective action
- Measure whether the analog input contact voltage level equals ground potential.
- Power-cycle to check; if the abnormality persists after reset, return the drive to the dealer or original manufacturer for inspection and repair. Remove the CN1 wiring and execute automatic correction to clear.