Description
The ASF01 board detected a mismatch in the general-purpose safety input signals.
Subcode description
The meaning of each sub code is
as follows:
1:GSIN1
2:GSIN2
Causes and remedies
| Cause | Remedy |
|---|---|
| Cable (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, check the following items. • Check the connection between the connected device receiving signal GSIN and the IM-YE250/5-80P terminal block board. • Check the cable connecting the IM-YE250/5-80P terminal block board and the ASF01 board. • Check the connectors and other connections of the connected device. |
| ASF01 board (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, replace the ASF01 board. For a system with multiple ASF01 boards connected, replace the ASF01 board connected to the GSIN signal that generated the alarm. |
| IM-YE250/5-80P terminal block board (abnormal) | 1. Reset the alarm. 2. If the alarm recurs, replace the IM-YE250/5-80P terminal-block board. For a system with multiple IM-YE250/5-80P terminal block boards connected, replace the IM-YE250/5-80P terminal block board connected to the control group that generated the alarm. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |