Description
The gun axis exceeded the software limit while pressuring operation is executed.
Subcode description
Sub Code: Signifies the axis in
which the alarm occurred
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Check the gun axis home position setting. [Opening side] Reset the software limit on the gun opening side. (Parameters S1CxG800 and 810) [Closing side] Reset the soft limit on the gun-closing side. In this case, increase the travel distance by an amount equal to the tip wear. (Parameters S1CxG800 and 810) |
| Other | If the alarm occurs again after implementing the countermeasures, save CMOS.BIN in maintenance mode and inform our service department of the circumstances (operating procedure, etc.). |