[Cause]
The following operations were performed in the ventilation state through air washing operation (press the status key while holding down the SHIFT key). In order to prevent the gas from being turned on, the gas is automatically turned off when this alarm occurs.
- Start the program
- Switch to AUTO mode which disables the teach pendant
- On the welding system setting interface, change the setting of [Gas Purge Key] to invalid
[Countermeasure]
Do not perform the above operation while the gas is turned on based on the air purge operation. When you need to perform the above operations, please do it after turning off the gas.