[Cause]
A DDLM function call error occurred in the DP master software on the PROFIBUS board. The sub-error code shown in parentheses indicates the following status. For details, refer to “Format of DDLM Calls” in section 8.2 of “Draft Standard PROFIBUS-DP DIN 19245 Part3”.
+-------------+--------------+-------------------------------------------------------------------------------------------+ | Code Number | Status Value | Annotations | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 1 | UE | Remote DDLM/FDL interface error | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 2 | RR | Remote FDL entities are either under-resourced or unusable. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 3 | RS | A remote LSAP service or remote address cannot be started. Or the remote LSAP has not yet | | | | been launched. That is: | | | | - Remote sites are not DP sites. | | | | - The remote sites are not yet ready for these functions. | | | | - Remote sites correspond to other requests. | | | | - Cannot use the option service. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 4 | RA | Access to remote SAP blocked. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 17 | NA | Negative response. No response from remote sites. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 18 | DS | Local FDL/PHY entities cannot be used. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 19 | NO | The service is not available in this state. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 20 | LR | Local resources are not available. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 21 | IV | The requested parameter is illegal. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 22 | TO | Function timeout. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 193 | FE | A formatting error occurred in the requested frame. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 194 | NI | The functionality has not yet been installed. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 195 | AD | Access denied. | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 196 | EA | The area is too large (upload/download). | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 197 | LE | Data modules are too long (upload/download). | +-------------+--------------+-------------------------------------------------------------------------------------------+ | 198 | RE | The response frame has a formatting error. | +-------------+--------------+-------------------------------------------------------------------------------------------+
+-------------+--------------+--------------------------------------------------------------------------------------------+ | Code Number | Status Value | Annotations | +-------------+--------------+--------------------------------------------------------------------------------------------+ | 199 | IP | Invalid parameter. For example, the input/output byte count for the PROFIBUS master and | | | | slave interface is too large. Set the maximum number of DI/DO ports correctly on the | | | | PROFIBUS master setup interface. Set the following system variables to the maximum allowed | | | | values. | | | | $PRIMAVAR.$MAX_OUT_LEN = 32 => 128 | | | | $PRIMAVAR.$MAX_IN_LEN = 32 => 128 | +-------------+--------------+--------------------------------------------------------------------------------------------+ | 200 | SC | Sequence conflict. | +-------------+--------------+--------------------------------------------------------------------------------------------+ | 201 | SE | Sequence Error | +-------------+--------------+--------------------------------------------------------------------------------------------+ | 202 | NE | Area does not exist. | +-------------+--------------+--------------------------------------------------------------------------------------------+ | 203 | DI | Data incomplete. | +-------------+--------------+--------------------------------------------------------------------------------------------+ | 204 | NC | Host parameters are not compatible. | +-------------+--------------+--------------------------------------------------------------------------------------------+