Description
SERVO PACK ALARM (EAGL).
Subcode description
Subcode: SERVOPACK alarm (EAGL).
Causes and remedies
| Cause | Remedy |
|---|---|
| Servo unit (abnormal) | 1. A.720: Overload (continuous maximum) • Check whether the welding wire is touching the workpiece or another object • Check whether the wire feed resistance is too high • The servo unit may have failed. Replace the servo unit. 2. A.C90: Encoder communication error • The encoder cable may have a poor connection. Check the connections of the connectors at each part. • The encoder cable may be broken. Replace the encoder cable. • The servo unit may have failed. Replace the servo unit. 3. A.b33: Current detection error • The servo motor main circuit cable may have a poor connection. Check the connections of the connectors at each part. • The servo motor main circuit cable may be broken. Replace the servo motor main circuit cable. • The servo unit may have failed. Replace the servo unit. 4. A.100: Overcurrent detected • The servo motor main circuit cable may have a poor connection. Replace the servo motor main circuit cable. • The servo motor may have reached the end of its service life. Replace the servo motor. • The servo unit may have failed. Replace the servo unit. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |