Error handling: Controller power OFF.
Error reset: Not possible.
Description: The 5V power supplied from the control power supply AVR to the power sequence board is outside its rated value.
Main causes:
-
Incorrect voltage adjustment of the control power AVR.
-
A problem with the control power AVR.
-
A problem with the power sequence board.
Countermeasures:
-
Check the 5V voltage between the test pins on the power sequence board and adjust it to within 5.05 to 5.15V.
-
Replace the AVR.
-
Replace the power sequence board.