Description
This alarm occurs when an error is detected during the parameter checksum.
Subcode description
SVPxG parameter error
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (data error) | 1. Turn the power off and back on. 2. If the alarm recurs, initialize the corresponding parameter file in maintenance mode, then load the backed-up parameter file. |
| ACP01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ACP01 board. As a precaution, save CMOS.BIN in maintenance mode before replacing the board. After replacing the ACP01 board, remove the SD card from the original ACP01 board and insert it into the new ACP01 board. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |