Description
When the control power was turned ON, an ASF board setting error was detected.
Subcode description
ACP01 board was not able to
recognize SDCA01#5 board
when the control power turned
ON.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Check the following settings. • Check RSW on the SDCA01 board. The SDCA01 board with RSW"4" was not found. • The RSW setting duplicates that of another SDCA01 board. Check RSW. • Differs from the RSW setting of the ASF01 board on the SDCA01 board. Check the RSW settings. |
| Cable (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, check that the following cables and connectors are connected and fully inserted. • Cable for connector CN509 on the SDCA01 board • Cable for connector CN515/516 on the SDCA01 board • Cable for connector CN111 on the AIF01 board • Cable for CN155 on the CPS control power supply unit |
| SDCA01#5 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, check that the SDCA01#5 board is connected and fully inserted. |
| ACP01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ACP01 board. Save CMOS.BIN before replacing the board. After replacing the ACP01 board, remove the SD card from the original ACP01 board and insert it into the new ACP01 board. |