[Cause]
The leakage detection signal is at ON.
[Remedy]
Follow the steps below.
1. Eliminate the cause of leakage.
2. On the welding equipment I/O screen, confirm that the leakage current is set to OFF.
3. Reset.
4. In 2, if the leakage detection signal is not in OFF, confirm the wiring. Note that the polarity of the input signal is reversed.
代码