Error handling: Motor power OFF.
Error reset: Possible.
Content: A power abnormality signal has been input from the power supply unit control board (1VH).
Main causes:
-
Incorrect voltage adjustment of the controller power AVR.
-
A problem with the control power AVR.
-
The power supply unit (power supply unit control board) is faulty.
-
A problem with the servo board.
-
A ground fault or short circuit in the 5V power wiring.
-
An open circuit in the harness between the servo board (X503, X504, X505) and power supply unit control board (X304).
Countermeasures:
-
Check the 5V voltage between the test pins on the power sequence board and adjust it to within 5.05 to 5.15V.
-
Replace the AVR.
-
Replace the power supply unit control board.
-
Replace the servo board.
-
Check the 5V power supply wiring for a ground fault or short circuit.
-
Check the wiring between the servo board (X503, X504, X505) and power supply unit control board (X304).