Description
An error occurred in parameter which is used in the Safety Fieldbus function.
Subcode description
The processing-start wait-time value was not read correctly.
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (data error) | 1. Turn the power off and back on. 2. If the alarm recurs, save the following parameter files in online mode. Initialize the following parameter file in maintenance mode, and then load the saved parameter file. • SD.PRM |
| ACP01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ACP01 board. Save CMOS.BIN before replacing the board. After replacing the ACP01 board, remove the SD card from the original ACP01 board and insert it into the new ACP01 board. |
| ASF01 board (abnormal) | 1. Turn the power off and back on. 2. If the alarm recurs, replace the ASF01 board. |
| Other | If the alarm occurs again after implementing the countermeasures, contact our service department and describe the circumstances when CMOS.BIN was saved (operating procedure, etc.). |