Cause:
The interval length and segment length parameters of the specified-spacing intermittent welding statement are both 0.
Troubleshooting:
Check whether the interval-length and segment-length parameters of the intermittent-welding statement reporting the error are both 0.
Solution:
Modify the parameters of the intermittent-welding statement with a specified interval.
Case sharing:
WLinSeg2(cp0,cp1,real0,real1,arcsedgata0,arcdata0)
If real0 and real1 in the above statement are both 0, error 3745 is reported when it runs.