[Cause]
iRCalibration 's visual measurement error. The ratings detected were lower than the “scoring” set on the Visual Set.
[Countermeasure]
The response is through the following steps.
・ Check whether the target is visible in the image. Remove any obstructions. Alternatively, adjust the lighting and shutter speed so that the image outline can be seen clearly.
・ If the above alarm still occurs with appropriate brightness, check whether the camera is properly focused. If it is not, adjust the lens to focus it.
・ If the above countermeasures are ineffective, display the model and check that its outline features were taught correctly. If the model outline features were not taught correctly, reteach the model.
・ When all of the above-mentioned responses are ineffective, the rating is reduced.