Description
An error occurred in the ASCII-IF control processing.
Subcode description
The job's external-axis specification is incorrect. An attempt was made to record a job containing 2 or more external axes (station or base axes).
Causes and remedies
| Cause | Remedy |
|---|---|
| Software (incorrect setting) | Modify the job to execute the IBGNSTART instruction from a job containing only 1 external axis unit (station or base axis). |