[Cause]
A gun change instruction (connect/disconnect) was executed while a pneumatic gun was configured or gun change was disabled on the gun change initial settings screen.
[Countermeasure]
Open the gun change initial settings screen through a controlled start, set the equipment type to servo gun, and enable gun change.