Cause:
The segment-count parameter of the intermittent-welding statement with a specified segment count is 0.
Troubleshooting:
Check whether the segment count parameter of the intermittent welding statement reporting the error is 0.
Solution:
Set the segment count in the intermittent welding statement with a specified segment count to a value greater than or equal to 1.
Case sharing:
WlinSeg1(cp0,cp1,ulint0,real0,arcsedgata0,arcdata0)
If the segment count ulint0 in the statement above is 0, error 3738 will be reported during execution.