Error handling: Controller power OFF.
Error reset: Not possible.
Content: The 12V supply from the control power AVR to the power sequence board is outside the rated value.
Main causes:
-
The control power supply AVR is faulty.
-
A problem with the power sequence board.
-
A ground fault or short circuit in the 12V power supply wiring.
-
The power regeneration unit is faulty (E03).
Countermeasures:
-
Replace the AVR.
-
Replace the power sequence board.
-
Check the 12V power supply wiring for a ground fault or short circuit.
-
Replace the power regeneration unit.