Error handling: Motor power OFF.
Error reset: Not possible.
Content: The 5V supply from the control power AVR to the servo board is outside the rated value.
Main causes:
-
Incorrect voltage adjustment of the control power AVR.
-
A problem with the control power AVR.
-
A problem with the servo board.
-
The power module board is faulty.
-
A problem with the power supply unit (power supply unit control board).
-
The 5V power supply wiring has a ground fault or short circuit.
Countermeasures:
-
Check the 5V voltage between the test pins on the power sequence board and adjust it to within 5.05 to 5.15V.
-
Replace the AVR.
-
Replace the faulty servo board.
-
Replace the servo amplifier unit.
-
Replace the power supply unit control board.
-
Check the 5V power supply wiring for a ground fault or short circuit.